Rain Star Machine Water Turbine Leakage
2016-12-30
Remove the bolts that secure the water turbine seat plate and the components connected to the water turbine |
|
Remove the water turbine seat plate and impeller |
|
Remove the water turbine pulley and the elastic retaining ring at the main shaft, install an M10 bolt on the impeller side of the main shaft, and use a hammer to knock the bolt out of the main shaft. Remove the static ring of the mechanical seal.
|
|
Remove the water turbine pulley and the elastic retaining ring at the main shaft, install an M10 bolt on the impeller side of the main shaft, and use a hammer to knock the bolt out of the main shaft. Remove the static ring of the mechanical seal. |
|
Clean the dirt on the water turbine housing, apply lubricating grease to the bearings of the main shaft, install the water turbine, and install the elastic retaining ring |
|
Install the mechanical seal static ring and dynamic ring (both ends of the dynamic and static rings must be kept clean) |
|
Install the impeller and tighten the bolts. |
|
Install the water turbine seat plate and tighten the bolts (if the sealing strip on the housing is damaged, replace it and apply sealant for installation) |
|
Installing pulley |
|
Install the water turbine and its connecting components, and check the sealing with water. |
|
Required tools and items: 13 #, 16 #, 17 #, 18 # open-end wrenches, 16 #, 17 #, 19 # sockets, ratchet wrenches, internal circlip pliers, hammer, pliers, mechanical seals, glass glue Φ 5 sealing strips, glass glue gun. |
|